4-32 DocuTech 128/155/180 HighLight Color Installation Planning Guide
Prepare for installation
Wye (Star) service
Three-Phase Branch Circuit (3 lines and neutral, plus ground; total
5-wire system, including ground).
380/400/415v (220/230/240v per phase); taps set based on actual
on-site measurement.
220/380 volts (L-N/L-L) (+/- 10%)
230/400 volts (L-N/L-L) (+/- 10%)
240/415 volts (L-N/L-L) (+/- 10%)
Network requirements
This section describes the network requirements for installing one
or more DocuTech printers. Work with your Network Administrator
to assess what type of network you have and what modifications
need to be made to supply an Ethernet connection for the DocuSP
controller.
Network hardware
The Ethernet interface on the DocuSP controller is a 10/100/1000
MB per second twisted pair standard (10BaseT, 100Base T, or
1000BaseT). Attachment Unit Interface (AUI) Coax Ethernet is
enabled with an optional adapter cable.
The Ethernet connection to the DocuSP controller must be
compatible with the Institute of Electrical and Electronics
Engineers (IEEE) 802.3 standard.
Network protocols
The DocuSP controller supports TCP/IP, IPX/SPX, Socket TCP/IP,
and EtherTalk Link Access Protocol (ELAP) protocols if the proper
gateways are installed on the controller.
NOTE: The DocuSP controller does not provide Novell server
network services. If you plan to use the IPX/SPX protocol, you
must have a Novell server installed on your network.
Telephone requirements
One telephone line is recommended where the DocuTech printer
is installed.
Customer support
There will be times when the operator or administrator will need to
read the screen information from the DocuSP controller dialogs to
the customer support personnel. Therefore, it is necessary to
provide a telephone in close proximity to the DocuTech system so