4-34 DocuTech 128/155/180 HighLight Color Installation Planning Guide
Prepare for installation
Heat management
The DocuTech system produces significant amounts of heat when
running in a production environment. The heat produced by the
system must be considered when selecting a suitable location.
Heat management assessment process
Consult the site HVAC engineer or contractor to determine
whether the heat output can be managed by air conditioning at the
site. Consider the following items when assessing the acceptable
environmental operating conditions for the system:
• heat output of the system when in operating mode (32,770
BTU/hour)
• current relative humidity and temperature of the site
• acceptable system environmental requirements
• high outside temperatures
• incoming airflow rate in total cubic feet per minute (CFM)
Heat Vent Kit option for the DT HLC 180
If the customer site in which the production publisher printer will be
located is small and adequate venting is an issue, a heat vent kit is
available for purchase by the customer.
Installed on the IOT, the Heat Vent Kit provides the customer with
the ability to vent the excess heat produced by the printer through
the ceiling.
A Heat Vent Extension Kit is also available and is used to vent
heat from the interposer module.
Both kits are available through CAS and include installation
instructions for the CSE. Also, a kit is available for the 50Hz or 60
Hz configuration.
Item Order Number
IOT Heat Vent Kit 98K06472
Interposer Heat Vent
Extension Kit
98K42600