4-26 DocuTech 128/155/180 HighLight Color Installation Planning Guide
Prepare for installation
Printer/HLC
with inverter
feeder/
stacker and
one feeder/
stacker
W=175 in / 444.5 cm
D=42 in / 106.6 cm (with all
front and rear covers)
Total space required (plus
access):
264.6 in (W) x 142.0 in (D) /
672 cm x 361 cm
3129 lbs
1419.3
kg
Operating:
32,770 BTU per
hr.
Standby:
4,454 BTU per
hr.
Energy Saver:
2,700 BTU per
hr.
60 Hz
120/240 VAC or 120/
208 VAC; 50 amp
service; NEMA L14-
50R; KVA 7.3
(operating)
(2 Cords required)
120/208 VAC (182 V to
220 V), KVA 7.3
(operating)
Cord 1: 50 amp,
NEMA 14-50R
Cord 2: 30 amp,
NEMA 14-30R
50 Hz:
Consult your local
service representative.
Printer/HLC
with inverter
feeder/
stacker and
two feeder/
stackers
W=207 in / 525.7 cm
D=42 in / 106.6 cm (with all
front and rear covers)
Total space required
(plus access):
296.6 in (W) x 142.0 in (D) /
753 cm x 361 cm
3650 lbs
1655 kg
Operating:
32,770 BTU per
hr.
Standby:
4,454 BTU per
hr.
Energy Saver:
2,700 BTU per
hr.
60 Hz:
120/240 VAC or 120/
208 VAC; 50 amp
service; NEMA 14-
50R, KVA
8.1(operating)
(2 Cords required)
120/208 VAC (182 V to
220 V), KVA
8.1(operating)
Cord 1: 50 amp,
NEMA 14-50R
Cord 2: 30 amp,
NEMA 14-30R
50 Hz:
Consult your local
service representative
Device Dimensions (width and
depth)
Total
Weight
Heat dissipation Power requirements