DocuTech 128/155/180 HighLight Color Installation Planning Guide 4-29
Prepare for installation
60 Hz printer outlet voltages
The following table shows the voltages for the outlets on your
printer. All power outlets must have a dedicated circuit for each
system equipment piece. Make sure each power cord has a
separate circuit.
Table 4-10. Printer (60 Hz) voltage requirements at power
outlet.
50 Hz printer outlet voltages
All power outlets must have a dedicated circuit for each system
equipment piece. Make sure power cord has a separate circuit.
NOTE: Consult with your service representative to ensure that the
installation conforms to your local electrical requirements.
WYE (or Star)
configurations– 50 Hz
For the 50 Hz WYE configuration, measure the WYE or Star
connection voltages at the power source. Three-phase branch
circuit (3 lines and neutral, plus ground. Total 5-wire system,
including ground).
The following tables list the 50 Hz WYE/Star printer outlet
information for 380,400, and 415 volts.
Table 4-11. Printer (50 Hz) WYE (Star) 415 voltage
Service outlet
configuration
(3 wires plus ground)
Measurement
of wiring
Nominal Range
4 Wire Line 1 to
neutral
120 V RMS 107-127 V RMS
4 Wire Line 2 to
neutral
120 V RMS 107-127 V RMS
4 Wire Neutral to
ground
00-10 V RMS
4 Wire Line 1 to line 2 208 V RMS 182-220 V RMS
4 Wire Line 1 to line 2 240 V RMS 210-254 V RMS
Service
outlet
configuration
Measurement
of wiring
Nominal Range
5 Wire 415 V Line 1 to line 2 415 V RMS 374-457 V RMS
5 Wire 415 V Line 2 to line 3 415 V RMS 374-457 V RMS